Hotline

(028) 3882 8382

Tài Khoản

HV HIPOT GDSL-A-5000 Primary Current Injection Test Set (0~12V; AC0~5000A)0
HV HIPOT GDSL-A-5000 Primary Current Injection Test Set (0~12V; AC0~5000A)0

HV HIPOT GDSL-A-5000 Primary Current Injection Test Set (0~12V; AC0~5000A)


Thương hiệu:

HV HIPOT

Model:

GDSL-A-5000

Xuất xứ:

CHINA

Bảo hành:

12 tháng

Đơn vị tính:

cái

VAT:

10 %


Số lượng:
  • Max. Output current: AC Single-phase 5000A*3 groups
  • Circuit mode: Electric voltage regulator with special craft
  • Duty cycle: 8 hours
  • AC Input
  • Phase line: 3P
  • Voltage: 208V±10%, 60Hz±2% 3Φ4W
  • Input current: 288A
  • Output
  • Phase line: 3Φ4W
  • Voltage: 0~12V Auto switching
  • Current:
  • - AC0~5000A continuous adjustable, stepless speed regulation;
  • - 3-phase can output at one time, can output single-phase, also can split phase output;
  • - Tow kinds of output-manual mode and auto mode;
  • Rated capacity: 180kVA
  • Stabilized current accuracy: Output current≤±0.5%
  • Output terminal: Wiring terminal
  • Protection: The electronic circuit rapidly detects over voltage, over current, over temperature, phase loss, etc., automatic tripping protection and alarm device, the voltage and the current is zero in non-test status.
  • Accuracy
  • Source effect: ≤0.3% of rated value
  • Time drift: ≤1% of rated value
  • Temp. drift: ≤0.04% of rated value/°C
  • Load effect: ≤1% of rated value (Output voltage change rate due to the output current change from zero to the rated value.)
  • Ripple voltage: ≤1% of rated value+10mV
  • Others
  • Line regulation: 0.1%
  • Load regulation: 0.1%
  • Display and settings
  • Voltage meter display: True color LCD and digital display instrument (display accuracy: 0.1V display error: ≤1.0%±3 digit)
  • Current meter display: True color LCD and digital display instrument (5 digits display, display accuracy: 0.1A display error: ≤1.0%±3 digit)
  • Adjustment setting: Current (High precision potentiometer adjustment)
  • System
  • Efficiency: ≥90%
  • Resistance: Withstand voltage insulation resistance AC1800V 1min, 20MW
  • Cooling device: Forced fan cooling
  • Noise: <60dB (1mm in front of the device)
  • CT accuracy: 0.2%
  • Protection level: IP20
  • Working environment
  • Working mode: Long time temperature rise test
  • Temperature: -10°C~50°C
  • Humidity: 0-90% (non-condensing)
  • Altitude: <1500m
  • Appearance
  • Structure: Integration
  • Dimension: Customized
  • Weight: Approx. 2.5T
  • Temperature inspection: 26-way module
  • A class thermocouple: PT100 with 6m line * 26pcs

Xem thêm
Ẩn bớt nội dung
HV HIPOT GDSL-A-5000 Primary Current Injection Test Set (0~12V; AC0~5000A)
Xem thêm
Ẩn bớt nội dung
Xem thêm
Ẩn bớt nội dung


Xem thêm
Ẩn bớt nội dung
Bạn hãy Đăng nhập để đánh giá sản phẩm này.
Xem thêm
Ẩn bớt nội dung
  • Max. Output current: AC Single-phase 5000A*3 groups
  • Circuit mode: Electric voltage regulator with special craft
  • Duty cycle: 8 hours
  • AC Input
  • Phase line: 3P
  • Voltage: 208V±10%, 60Hz±2% 3Φ4W
  • Input current: 288A
  • Output
  • Phase line: 3Φ4W
  • Voltage: 0~12V Auto switching
  • Current:
  • - AC0~5000A continuous adjustable, stepless speed regulation;
  • - 3-phase can output at one time, can output single-phase, also can split phase output;
  • - Tow kinds of output-manual mode and auto mode;
  • Rated capacity: 180kVA
  • Stabilized current accuracy: Output current≤±0.5%
  • Output terminal: Wiring terminal
  • Protection: The electronic circuit rapidly detects over voltage, over current, over temperature, phase loss, etc., automatic tripping protection and alarm device, the voltage and the current is zero in non-test status.
  • Accuracy
  • Source effect: ≤0.3% of rated value
  • Time drift: ≤1% of rated value
  • Temp. drift: ≤0.04% of rated value/°C
  • Load effect: ≤1% of rated value (Output voltage change rate due to the output current change from zero to the rated value.)
  • Ripple voltage: ≤1% of rated value+10mV
  • Others
  • Line regulation: 0.1%
  • Load regulation: 0.1%
  • Display and settings
  • Voltage meter display: True color LCD and digital display instrument (display accuracy: 0.1V display error: ≤1.0%±3 digit)
  • Current meter display: True color LCD and digital display instrument (5 digits display, display accuracy: 0.1A display error: ≤1.0%±3 digit)
  • Adjustment setting: Current (High precision potentiometer adjustment)
  • System
  • Efficiency: ≥90%
  • Resistance: Withstand voltage insulation resistance AC1800V 1min, 20MW
  • Cooling device: Forced fan cooling
  • Noise: <60dB (1mm in front of the device)
  • CT accuracy: 0.2%
  • Protection level: IP20
  • Working environment
  • Working mode: Long time temperature rise test
  • Temperature: -10°C~50°C
  • Humidity: 0-90% (non-condensing)
  • Altitude: <1500m
  • Appearance
  • Structure: Integration
  • Dimension: Customized
  • Weight: Approx. 2.5T
  • Temperature inspection: 26-way module
  • A class thermocouple: PT100 with 6m line * 26pcs

HV HIPOT GDSL-A-5000 Primary Current Injection Test Set (0~12V; AC0~5000A)


Bạn hãy Đăng nhập để đánh giá sản phẩm này.

Bình luận

LIÊN HỆ VỚI CHÚNG TÔI

CÔNG TY TNHH IMALL VIỆT NAM
Số điện thoại

(028) 3882 8382

098 7777 209

Địa chỉ

52/1A Huỳnh Văn Nghệ, P.15, Q.Tân Bình, TP.HCM

Top