Specifications | Range | UT206B |
AC current (A) | 1000A | ±(2%+5) |
AC current frequency response | 50Hz~60Hz | |
Inrush current (A) | 1000A | ±(10%+10) |
AC voltage (V) | 6V | ±(1.2%+3) |
60V/600V/1000V | ±(1%+8) | |
DC voltage (V) | 600mV | ±(0.8%+3) |
6V/60V | ±(0.5%+5) | |
600V | ±(0.5%+5) | |
1000V | ±(0.5%+5) | |
Low pas filter (LPF ACV) | 600V/1000V | ±(2%+5) |
AC voltage frequency response | 40Hz~400Hz | |
LoZ ACV | 600V/1000V | ±(2%+5) |
Resistance (Ω) | 600Ω | ±(1%+3) |
6KΩ/60KΩ/600KΩ | ±(1%+2) | |
6MΩ/60MΩ | ±(2%+8) | |
Capacitance (F) | 60nF | ±(4%+25) |
600nF/6μF/60μF/600μF | ±(4%+5) | |
6mF/60mF | ±(10%+9) | |
Temperature (℃) | -40℃~300℃ | ±(1%+20) |
300℃~1000℃ | ±(1%+2) | |
Low voltage frequency (Hz) | 10Hz~1MHz | ±(0.1%+3) |
Duty cycle (%) | 10%~90% | ±(2.6%+7) |
Features | ||
Display count | 6000 | |
Jaw opening | 42mm | |
Current frequency | 50Hz~60Hz | |
High voltage frequency | 40Hz~400Hz | |
Analog bar | 31 | |
Auto power off | √ | |
Continuity test | √ | |
Auto/Manual range | √ | |
Low battery indication | √ | |
Diode test | √ | |
Relative mode/Data hold | √ | |
MAX/MIN | √ | |
Function selection | √ | |
Flashlight | √ | |
Wake-up function | √ | |
Auto power off current: <50μA | √ | |
Flexible current probe (optional) | Extends to 3000A | √ |
Input impedance (ACV/DCV) | ≥10MΩ | √ |
General Characteristics | ||
Power | 1.5V battery (R03) x 3 | |
Display | 43mm x 45mm | |
Product color | Red and grey |
Specifications | Range | UT206B |
AC current (A) | 1000A | ±(2%+5) |
AC current frequency response | 50Hz~60Hz | |
Inrush current (A) | 1000A | ±(10%+10) |
AC voltage (V) | 6V | ±(1.2%+3) |
60V/600V/1000V | ±(1%+8) | |
DC voltage (V) | 600mV | ±(0.8%+3) |
6V/60V | ±(0.5%+5) | |
600V | ±(0.5%+5) | |
1000V | ±(0.5%+5) | |
Low pas filter (LPF ACV) | 600V/1000V | ±(2%+5) |
AC voltage frequency response | 40Hz~400Hz | |
LoZ ACV | 600V/1000V | ±(2%+5) |
Resistance (Ω) | 600Ω | ±(1%+3) |
6KΩ/60KΩ/600KΩ | ±(1%+2) | |
6MΩ/60MΩ | ±(2%+8) | |
Capacitance (F) | 60nF | ±(4%+25) |
600nF/6μF/60μF/600μF | ±(4%+5) | |
6mF/60mF | ±(10%+9) | |
Temperature (℃) | -40℃~300℃ | ±(1%+20) |
300℃~1000℃ | ±(1%+2) | |
Low voltage frequency (Hz) | 10Hz~1MHz | ±(0.1%+3) |
Duty cycle (%) | 10%~90% | ±(2.6%+7) |
Features | ||
Display count | 6000 | |
Jaw opening | 42mm | |
Current frequency | 50Hz~60Hz | |
High voltage frequency | 40Hz~400Hz | |
Analog bar | 31 | |
Auto power off | √ | |
Continuity test | √ | |
Auto/Manual range | √ | |
Low battery indication | √ | |
Diode test | √ | |
Relative mode/Data hold | √ | |
MAX/MIN | √ | |
Function selection | √ | |
Flashlight | √ | |
Wake-up function | √ | |
Auto power off current: <50μA | √ | |
Flexible current probe (optional) | Extends to 3000A | √ |
Input impedance (ACV/DCV) | ≥10MΩ | √ |
General Characteristics | ||
Power | 1.5V battery (R03) x 3 | |
Display | 43mm x 45mm | |
Product color | Red and grey |
Product sets
Brand: UNI-T
UNI-T UT206B 1000A True RMS Digital Clamp Meter
UT200 series are 6000-count digital clamp meters with auto range, large LCD, true RMS, autoscale memory, and NCV functions. They conform to CAT III 1000V/CAT IV 600V safety rating andcertified by CE/ETL. The UT206B, UT207B, and UT208B come with LoZ mode for eliminating ‘ghost ’voltage, LPF ACV function for measuring INV and VFD voltage, and inrush current modefor capturing transient current. The UT206B and UT208B also feature high-precision temperature measurement with 0.1 °C resolution, and can be equipped with a flexible current probe toextend the AC current measurement range to 3000A.
Brand
UNI-T
Reviews
There are no reviews yet.
Be the first to review “UNI-T UT206B 1000A True RMS Digital Clamp Meter”
You must be logged in to post a review.
Reviews
There are no reviews yet.