Measuring ranges: 30 A / 300 A / 3000 A AC
Output sensitivity: 100 mV / 10 mV / 1 mV per A
(AC coupled)
Accuracy (45-65Hz): ± 1% of reading ± 0.1 A 30 / 300 A
± 1% of reading: ± 1 A 3000 A
Minimum load: 100 kΩ for specified accuracy
Frequency range: 10 Hz to 20 kHz (-1 dB)
Phase (45-65Hz): <± 1°
Position sensitivity: ± 2% of reading
External field: ± 0.25% of range with cable >100 mm from the probe
Noise: 80 mA RMS 30 A, 400 mA RMS 300 A / 3000 A
Temperature coeff.: ± 0.1 % /°C
Power supply: Two AA MN1500 LR6 alkaline batteries or an external power supply (+3 V / 100 mA)
Battery life
1000 hours typical (TA325)
2000 hours typical (TA326)
External Power: ia 2.1 mm (0.08") mini power connector
Low battery: Indicated by an orange LED
Overload: Indicated by a red LED
Enclosure
Material: ARNITE T06-200SNF, UL94 V0
Degree of Protection: IP40
Dimensions: 110 (l) x 65 (w) x 23 (d) mm
Output connection TA325: 0.5 m coax cable with 3 shrouded BNC connectors