  • CERTIFIER OF SINGLE PHASE PV INSTALLATION
    • DC Voltage: 15.0 ÷  1499.9V; ± (0.5%rdg + 2dgt)
    • AC TRMS Voltage: 50.0 ÷ 265.0 V; ± (0.5%rdg + 2dgt)
    • DC current  (by external transducer clamp):
    • -1100 ÷ -5/ 5 ÷ 1100; ± (0.5%rdg + 0.6mV)
    • AC TRMS Current (by external transducer clamp): 1 ÷ 1200; 47.5 ÷ 63.0; ± (0.5%rdg + 0.6mV)
    • 1< FS ≤ 10: 0.05; 0.01
    • 10< FS ≤ 100: 0.5; 0.1
    • 100< FS ≤ 1000: 5A; 1
    • DC Power (Vmeas > 150V):
    • 1< FS ≤ 10: 0.000k ÷ 9.999k;, 10.00k ÷ 99.99k ±(0.7%rdg + 3dgt)(Imeas < 10%FS)
    • 10< FS ≤ 100:0.000k ÷ 9.999k; 10.00k ÷ 99.99k; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); 100.0k ÷ 999.9k ; ±(0.7%rdg)(Imeas ≥ 10%FS)
    • 100< FS ≤ 1000:0.00k ÷ 99.99k; 100.0k ÷ 999.9k; 1000k ÷ 9999k ; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); ±(0.7%rdg)(Imeas ≥ 10%FS)
    • AC Single phase power (@ PF = 1, Vmeas > 200V):
    • 1< FS ≤ 10: 0.000k ÷ 9.999k;, 10.00k ÷ 99.99k ±(0.7%rdg + 3dgt)(Imeas < 10%FS)
    • 10< FS ≤ 100:0.000k ÷ 9.999k; 10.00k ÷ 99.99k; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); 100.0k ÷ 999.9k ; ±(0.7%rdg)(Imeas ≥ 10%FS)
    • 100< FS ≤ 1000:0.00k ÷ 99.99k; 100.0k ÷ 999.9k; 1000k ÷ 9999k ; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); ±(0.7%rdg)(Imeas ≥ 10%FS)
    • Frequency: 47.5 ÷ 63.0Hz; ±(0.2%rdg+1dgt)
    • Irradiance (by reference cell) : 1 ÷ 65.0; ±(1.0%rdg + 5dgt)
    • Temperature (by external probe PT1000): -20.0 ÷ 100.0; ± (1.0%rdg +1°C)
  • I-V CURVE and IVCK MEASUREMENTS
    • I-V, IVCK: VDC Voltage @ OPC: 15.0 ÷1499.9; ± (0.5%rdg + 2dgt)
    • I-V, IVCK: IDC Current @ OPC: 0.10 ÷ 15.00; ± (1.0%rdg + 2dgt)
    • I-V: DC Power @ OPC (Vmpp >30V, Impp >2A): 50 ÷ 99999; ± (1.0%rdg + 6dgt)
    • I-V, IVCK: VDC Voltage (@ STC): 5.0 ÷ 999.9; ± (4.0%rdg + 2dgt)
    • I-V: IDC Current (@ STC): 0.10 ÷ 99.00; ± (4.0%rdg + 2dgt)
    • I-V: DC Power @ STC (Vmpp >30V, Impp >2A): 50 ÷ 99999; ± (5.0%rdg + 1dgt)
    • Irradiance (with reference cell):  1.0 ÷ 100.0; ÷(1.0%rdg+5dgt)
    • Temperature of module (with auxiliary PT1000 probe): -20.0 ÷ 100.0; ÷(1.0%rdg+1°C)

Brand: HT Instruments

HT Instruments SOLAR IVe I-V curve tracer up to 15A or 1500VDC and PV efficiency logger (15A, 1500VDC)

Brand

HT Instruments

Reviews

There are no reviews yet.

Be the first to review “HT Instruments SOLAR IVe I-V curve tracer up to 15A or 1500VDC and PV efficiency logger (15A, 1500VDC)”

Specifications
  • CERTIFIER OF SINGLE PHASE PV INSTALLATION
    • DC Voltage: 15.0 ÷  1499.9V; ± (0.5%rdg + 2dgt)
    • AC TRMS Voltage: 50.0 ÷ 265.0 V; ± (0.5%rdg + 2dgt)
    • DC current  (by external transducer clamp):
    • -1100 ÷ -5/ 5 ÷ 1100; ± (0.5%rdg + 0.6mV)
    • AC TRMS Current (by external transducer clamp): 1 ÷ 1200; 47.5 ÷ 63.0; ± (0.5%rdg + 0.6mV)
    • 1< FS ≤ 10: 0.05; 0.01
    • 10< FS ≤ 100: 0.5; 0.1
    • 100< FS ≤ 1000: 5A; 1
    • DC Power (Vmeas > 150V):
    • 1< FS ≤ 10: 0.000k ÷ 9.999k;, 10.00k ÷ 99.99k ±(0.7%rdg + 3dgt)(Imeas < 10%FS)
    • 10< FS ≤ 100:0.000k ÷ 9.999k; 10.00k ÷ 99.99k; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); 100.0k ÷ 999.9k ; ±(0.7%rdg)(Imeas ≥ 10%FS)
    • 100< FS ≤ 1000:0.00k ÷ 99.99k; 100.0k ÷ 999.9k; 1000k ÷ 9999k ; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); ±(0.7%rdg)(Imeas ≥ 10%FS)
    • AC Single phase power (@ PF = 1, Vmeas > 200V):
    • 1< FS ≤ 10: 0.000k ÷ 9.999k;, 10.00k ÷ 99.99k ±(0.7%rdg + 3dgt)(Imeas < 10%FS)
    • 10< FS ≤ 100:0.000k ÷ 9.999k; 10.00k ÷ 99.99k; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); 100.0k ÷ 999.9k ; ±(0.7%rdg)(Imeas ≥ 10%FS)
    • 100< FS ≤ 1000:0.00k ÷ 99.99k; 100.0k ÷ 999.9k; 1000k ÷ 9999k ; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); ±(0.7%rdg)(Imeas ≥ 10%FS)
    • Frequency: 47.5 ÷ 63.0Hz; ±(0.2%rdg+1dgt)
    • Irradiance (by reference cell) : 1 ÷ 65.0; ±(1.0%rdg + 5dgt)
    • Temperature (by external probe PT1000): -20.0 ÷ 100.0; ± (1.0%rdg +1°C)
  • I-V CURVE and IVCK MEASUREMENTS
    • I-V, IVCK: VDC Voltage @ OPC: 15.0 ÷1499.9; ± (0.5%rdg + 2dgt)
    • I-V, IVCK: IDC Current @ OPC: 0.10 ÷ 15.00; ± (1.0%rdg + 2dgt)
    • I-V: DC Power @ OPC (Vmpp >30V, Impp >2A): 50 ÷ 99999; ± (1.0%rdg + 6dgt)
    • I-V, IVCK: VDC Voltage (@ STC): 5.0 ÷ 999.9; ± (4.0%rdg + 2dgt)
    • I-V: IDC Current (@ STC): 0.10 ÷ 99.00; ± (4.0%rdg + 2dgt)
    • I-V: DC Power @ STC (Vmpp >30V, Impp >2A): 50 ÷ 99999; ± (5.0%rdg + 1dgt)
    • Irradiance (with reference cell):  1.0 ÷ 100.0; ÷(1.0%rdg+5dgt)
    • Temperature of module (with auxiliary PT1000 probe): -20.0 ÷ 100.0; ÷(1.0%rdg+1°C)

Brand: HT Instruments