  • General Specifications
    Display: ¼ VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast, text and graphics in color
    Quality: Developed, designed and manufactured according to DIN ISO 9001
    Memory: 4 MB Flash memory, 3.5 MB for measuring data
    Interface: RS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS- 232 interface (9-pole extension cable)
    Sample rate: 10.24 kHz
    Line frequency: 50 Hz or 60 Hz, user-selectable, with automatic synchronization
    Power supply: NiMH battery-pack, with ac adapter (15 V to 20 V/0.8 A)
    Operation time with battery: Typical > 12 hours without backlight and > 6 hours with backlight high
    Dimensions: 240 mm x 180 mm x 110 mm
    Weight: 1.7 kg, including battery
    Ambient conditions
    Working temperature range: -10 °C to +50 °C
    Storage temperature range: -20 °C to +60 °C
    Operating temperature range: 0 °C to +40 °C
    Reference temperature range: 23 °C ± 2 °C
    Note: The above terms are defined in European Standards. To calculate the specification at any point in the working temperature range, use the temperature coefficient below.
    Temperature coefficient: ± 0.1 % of the measured value per °C from the reference
    Intrinsic error: Refers to reference temperature, maximum deviation is guaranteed for two years
    Operating error: Refers to operating temperature range, maximum deviation is guaranteed for two years
    Climatic class: C1 (IEC 654-1) -5 °C to +45 °C, 5% to 95% RH, no dew
    Housing: Cycoloy shock and scratch proof thermoplast V0-type (non-flammable) with rubber protection holster
    EMC
    Emission: IEC/EN 61326-1:1997 class B
    Immunity: IEC/EN 61326-1:1997
    Safety Specifications:
    Safety: IEC 61010-1 600 V CAT III, double or reinforced insulation, pollution degree 2
    Protection: P65; EN60529 (refers only to the main housing without the battery compartment) RMS values are measured with a 20 ms resolution.
    V-rms wye measurement:
    Measuring range: 57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/400 V/417 V/480 V ac
    Intrinsic error: ± (0.2% of measured value + 5 digits)
    Operating error: ± (0.5% of m. v. + 10 digit)
    Resolution: 0.1 V
    V-rms delta measurement
    Measuring range: 100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/690 V/720 V/830 V ac
    Intrinsic error: ± (0.2% of m. v. + 5 digit)
    Operating error: ± (0.5 % of m. v. + 10 digit)
    Resolution: 0.1 V
    A-rms measurement
    Flexi set I ranges: 15 A/150 A/3000 A rms (at sine)
    Current clamp ranges: 1 A/10 A
    Resolution: 0.01 A
    Ranges 150 A/3000 A and 1 A/10 A
    Operating error: ± (1 % of m. v. + 10 digit)
    Ranges 15 A
    Intrinsic error: ± (0.5 % of m. v. + 20 digit)
    Operating error: ± (1 % of m. v. + 20 digit) The errors of the current probes are not considered.
    By using Flexi-Set
    Flexi Set measuring error: ± (2% of m. v. + 10 digit)
    Position influence: ± (3 % of m. v. + 10 digit)
    CF (typical): 2.83
    Note: When using Flexi Set please make sure to position the conductor opposite to the Flexi Set-lock
    Power measurement (P - Active, S - Apparent, Q- reactive, D - Distorting
    Measuring range: see V rms and A rms measurement Power errors are calculated by adding the errors of voltage and current Additional error due to power factor PF Specified error x (1-[PF]) Maximum range with voltage range 830 V delta-connection and 3000 A current range is 2.490 MW, higher displayed values possible when using PTs and CTs with ratio feature
    Intrinsic error: ± (0.7 % of m.v. +15 digit)
    Resolution: 1 kW
    Operating error: ± (1.5 % of m.v. + 20 digit) Typical range with voltage range 230 V wye connection and 150 A current range is 34.50 KW.
    Intrinsic error: ± (0.7 % of m.v. +15 digit)
    Resolution: 1 W to 10 W
    Operating error: ± (1.5 % of m.v. + 20 digit) The errors of the current sensors themselves have not been considered.
    Energy measurement (kWh, KVAh, kVARh)
    Intrinsic error: ± (0.7 % of m.v.+ F variation error* + 15 digit)
    Resolution: 1 W to 10 W
    Operating error: ± (1.5 % of m.v. + F variation error* + 20 digit) *Frequency variation error
    PF (Power factor)
    Range: 0.000 to 1.000
    Resolution: 0.001
    Accuracy: ±1 % of full scale
    Frequency measurement
    Measuring range: 46 Hz to 54 Hz and 56 Hz to 64 Hz
    Intrinsic error: ± (0.2 % of m. v. + 5 digit)
    Operating error: ± (0.5 % of m. v.+ 10 digit)
    Resolution: 0.01 Hz
    Harmonics
    Measuring range: To 50th harmonic (< 50 % of nom)
    Accuracy
    Vm, Im, THDV, THDI: IEC 61000-4-7:2002, Class II
    Vm ≥ 3% Vn: ± 5% Vm
    Vm < 3 % Vnom: ±0.15% Vnom
    Im ≥ 10 % Inom: ± 5% Im
    Im < 10 % Inom: ± 0 5% Inom
    THDV: for THD < 3% ± 0.15% at Vnom for THD ≥ 3% ± 5% at Vnom
    THDI: for THD < 10% ± 0.5% at Inom for THD ≥ 10% ± 5% at Inom
    Vnom: Normal voltage range
    Inom: Nominal current range Vm and Im are measured values of harmonic m
    Events
    Detection of voltage dips, voltage swells and voltage interruptions with a 10 ms resolution and measuring error of the half period sine wave of rms.
    Intrinsic error: ± (1% of m.v. + 10 digit)
    Operating error: ± (2% of m.v. + 10 digit)
    Resolution: 0.1 V
Xem thêm
Ẩn bớt nội dung
Xem thêm
Ẩn bớt nội dung
Xem thêm
Ẩn bớt nội dung
Xem thêm
Ẩn bớt nội dung
Bạn hãy Đăng nhập để đánh giá sản phẩm này.
Xem thêm
Ẩn bớt nội dung

Bình luận

LIÊN HỆ VỚI CHÚNG TÔI

CÔNG TY TNHH IMALL VIỆT NAM
Số điện thoại

(028) 3882 8382

098 7777 209

Địa chỉ

52/1A Huỳnh Văn Nghệ, P.15, Q.Tân Bình, TP.HCM

Top